To read a mechanical seal drawing for a replacement, identify the seal type and its parts from the cross section and the parts list, then take the drawing number and revision, the fitting dimensions and the material codes off the sheet. Those four together specify the seal that has to go back into the pump.

Read every letter and code against the legend of the maker who drew it.

Reading the Cross Section

The cross section shows the seal cut along the shaft axis, so every internal part is visible in its working position, along with how it fits against the shaft, the gland and the seal chamber. For the names and jobs of the individual parts, see our guide to the parts of a mechanical seal.

Which Side Faces the Pump

The process side is the side where the flush port enters the gland; the atmosphere side is where the quench inlet and outlet ports sit. If the drawing shows a throat bushing, that end faces the pump.

Identifying the Parts in the Section

Every seal section, whatever the design, shows the same four groups of parts:

  • Seal face pair: the rotating and stationary faces, drawn touching at the sealing interface.
  • Secondary seals: O-rings, gaskets, wedges, boots, or metal or elastomer bellows.
  • Springs and loading mechanism: one large spring, several small springs, leaf or wave springs, or a bellows doing the same job.
  • Structural components and hardware: the gland, sleeve, lock ring and the screws and pins that hold them together.

The shape drawn in each group places the seal in a family. A single coil spring, a ring of small springs or a welded metal bellows each points to a different design.

Cartridge or Component Seal

A cartridge seal drawing shows the sleeve, the gland, the collar that locks the seal to the shaft (set screw or clamp style) and a setting device as parts of the seal itself, inside its outline and in its parts list.

A component seal drawing shows the rotary and stationary units as separate loose parts. The sleeve and gland they mount on belong to the pump and usually carry the pump’s part numbers, or none at all.

A cartridge is ordered as one pre-assembled unit to fit the gland and seal chamber; a component seal is ordered to fit the pump’s own sleeve and gland. Our comparison of component vs cartridge mechanical seals covers what changes in service.

Matching Item Numbers to the Parts List

Each balloon on the drawing, the circled number at the end of a leader line, carries an item number that points to one row of the parts list. That row gives the part number, the description, the quantity and often the material.

The parts list normally sits just above the title block at the bottom right of the sheet. On larger seals it is a separate sheet.

When only a face, a spring set or the O-rings have to be replaced, find the balloon on that part, then read the part number for that item in the parts list. Some makers print a standard part number to DIN 24250 beside their own item number.

The Dimensions a Replacement Must Match

A replacement has to match the fitting dimensions shown on the seal assembly drawing: shaft or sleeve diameter, seal chamber bore and depth, gland pilot, stud diameter, stud bolt pattern and the distance to the first obstruction outside the chamber. The drawing also gives the setting length, the axial position that sets the spring compression.

For a component seal, the fitting dimensions are on the seal itself: seal head outside diameter, seat outside diameter (the counterbore it sits in), seat thickness and operating height. Some makers do not print these on the general drawing and refer you to a job-specific layout drawing instead.

The letters beside those dimensions are the drawing maker’s own. EagleBurgmann labels the shaft diameter d1 on its MG9 sheet. Read every symbol against the legend on that drawing, or against the standard it names.

If the drawing is missing or illegible, the old seal and the seal chamber have to be measured instead; our guide on how to measure mechanical seals covers that.

Reading the Material Codes

Read each material code against the drawing maker’s own key and the component position the code sits in. The drawing gives the materials in the parts list, one per item, or in a separate face-kit table and notes (“standard O-ring material: Viton”). Many makers replace the material name with a code: one letter, or a letter and digit, per component position, sometimes strung together into a single designation.

The same letter can mean different materials. On EagleBurgmann’s MG9 sheet, silicon carbide is Q1 and “V” means aluminium oxide when it codes the seat and FKM when it codes the elastomer.

EN 12756, which replaced DIN 24960, defines a standard material code, so a drawing can carry either the standard code or the maker’s own. The drawing’s legend or notes have to tell you which.

An assembly drawing may also list the product the seal was selected for. Check that line before copying the materials: if the pump now handles something else, the materials are the place to revisit. Our overview of mechanical seal materials covers the face and elastomer options.

The Title Block: Drawing Number and Revision

The title block, normally at the bottom right of the sheet, identifies the drawing: company, title, drawing number, revision, sheet number and scale. The drawing number is the unique identifier of that seal design, and the revision identifies which version of it the sheet shows.

The revision matters because a seal built to a later revision can differ from the earlier one in a part, a material or a dimension, while keeping the same drawing number. Every change after release is recorded in the revision table, usually at the top right, so read that table to see what changed and when.

Two details are easy to miss:

  • Separate parts list: a parts list on its own sheet can carry a different revision from the drawing, because it may be revised on its own.
  • Superseded drawing: a drawing replaced by a new design states the number of the drawing that supersedes it, so the number on your copy may no longer be the current one.

When the Drawing Does Not Match the Installed Seal

When the drawing and the seal in the pump differ, match the seal in the pump, since it is the one that fits the chamber today. Measure it, or send it as a sample, and treat the drawing as supporting evidence.

Check two causes before ordering. The drawing may call for reworks to the pump (a machined bore, a changed sleeve), so a seal drawn for a reworked pump will not fit one that was never reworked, or the reverse. The drawing may also be an earlier revision than the seal actually fitted; the revision table and any part numbers marked on the old parts can show which.

Confirm the arrangement and the shaft rotation shown on the drawing against the actual pump as well. If the seal cannot be identified with confidence, our guide to identifying a mechanical seal walks through it without a drawing.

What to Send a Seal Supplier From the Drawing

Send the complete drawing, parts list sheet included, and point the supplier to these fields:

  • Drawing number and revision: from the title block, with the revision table if it is legible.
  • Maker’s reorder identifiers: the part code, order number or bill-of-material number printed on the drawing, which the original maker’s spares orders are placed against.
  • Item and part numbers: for the parts you need, if you are replacing parts and not the whole seal.
  • Fitting dimensions: as dimensioned on the drawing, with the maker’s legend.
  • Materials and codes: with the key, and the product the seal was selected for if the drawing lists it.

Photos of the old seal and its parts help confirm what the drawing says. Cowseal builds a replacement from the seal’s own drawing, its model or part number, or a sample of the old seal, and makes OEM-compatible mechanical seals for most designs from John Crane, Flowserve, EagleBurgmann, Chesterton, Flygt, Grundfos and other brands. A pump model alone does not identify the seal, so send one of those three.